c c0116/configure> $shell Do you want to start a shell? y # ps PID Uid VmSize Stat S-pri Command 1 0 672 S O 0 init 2 0 SW O 0 [keventd] 3 0 SWN O 0 [ksoftirqd_CPU0] 4 0 SW O 0 [kswapd] 5 0 SW O 0 [bdflush] 6 0 SW O 0 [kupdated] 7 0 SW O 0 [mtdblockd] 8 0 Z O 0 [kjournald] 34 0 SW O 0 [kjournald] 75 0 552 S F 127 ledwd 76 0 712 S O 0 /bin/sh /etc/init.d/rcSappl 77 0 664 S O 0 /sbin/syslogd -n -m 0 -i 4 -O /opt/log/message 78 0 632 S O 0 /sbin/klogd -n 79 0 680 S O 0 /bin/sh /opt/rc.d/rc.telnetd 80 0 680 S O 0 /bin/sh /opt/rc.d/rc.shell 104 0 DW O 0 [DSL watchdog] 110 0 608 S O 0 /sbin/ftpd -f /opt/rc.d/ftpd.conf 121 0 680 S O 0 /bin/sh /opt/rc.d/start 149 0 1080 S O 0 /opt/zebra/zebra -d -f /opt/zebra/zebra.conf 152 0 1908 S O 0 /opt/zebra/ospfd -d -f /opt/zebra/ospfd.conf 167 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 169 0 684 S O 0 /bin/sh /opt/rc.d/ecad start 173 0 548 S O 0 /sbin/telnetd -l /opt/mdsl/mdslui 176 0 604 S O 0 /opt/mdsl/mdslui 183 0 768 R O 0 /opt/bin/startxlib 184 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 185 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 186 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 187 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 188 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 189 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 190 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 191 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 192 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 193 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 194 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 195 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 196 0 2028 S O 0 /opt/elcproxy/elcproxy -d /opt/elcproxy -P /op 197 0 940 S O 0 /opt/mdsl/mdslui 201 0 664 S O 0 sh -c sh 202 0 732 S O 0 sh 203 0 736 R O 0 ps # exit c0116/configure> exit c0116> d c0116/diag> m SYSTEM: Date/Time: System input voltage: System temperature: degrees Celsius CPU load: ------------------------------------------------------------------------------- MDSL1:FramesTx FramesRx FrameBsy FrmTxErr FrmRxErrMODE:STATUS:Loop Loss [dB]:Link act cnt:Signal Noise Ratio [%]: ------------------------------------------------------------------------------- MDSL2:FramesTx FramesRx FrameBsy FrmTxErr FrmRxErrMODE:STATUS:Loop Loss [dB]:Link act cnt:Signal Noise Ratio [%]: ------------------------------------------------------------------------------- MDSL3:FramesTx FramesRx FrameBsy FrmTxErr FrmRxErrMODE:STATUS:Loop Loss [dB]:Link act cnt:Signal Noise Ratio [%]: ------------------------------------------------------------------------------- Enter to return to the command prompt or to reset counters...23-04-2007 10:38:0924.1 27 100%   master  1174 774 0 0 0Active 4.44 1 48.0   slave  532 1141 0 0 0Active 3.60 1 48.0 23-04-2007 10:38:1024.1 27 100%   master  1175 776 0 0 0Active 4.44 1 48.0   slave  532 1141 0 0 0Active 3.60 1 48.0 23-04-2007 10:38:1124.1 27 100%   master  1177 777 0 0 0Active 4.44 1 48.0   slave  532 1141 0 0 0Active 3.60 1 48.0  c0116/diag> exit c0116> restart *** Restart MDSL Router *** Warning: Connection with router will be lost after restart! Restart router? y rebooting... c0116>